Matrox Imaging Library (MIL) 10 Update 29
Matrox Radient eV-CXP Release Notes
September 2017
(c) Copyright Matrox Electronic Systems
Ltd., 1992-2017.
In the following animation, the board's decoder is set to trigger a
pulse only when a linear stage is moving forward. The counter
decrements when the stage moves in reverse. The grab is only
triggered when the counter hits a new positive value; as such, no
line that was already grabbed will be grabbed again. For more
information, see the Example 2 code snippet, found on the
milRadientCXP page in this section of the help file.