MIL_CONST_TEXT_PTR FileName, | //in |
MIL_ID SystemId, | //in |
MIL_INT64 ControlFlag, | //in |
MIL_ID *ContextIdPtr | //out |
This function restores a String Reader context that was previously saved to a file, using MstrSave() or MstrStream(). This function restores all of the String Reader context's settings (including font and string model settings) that were in effect when the String Reader context was saved. A restored String Reader context is not preprocessed; therefore, you must call MstrPreprocess() before performing a read with MstrRead().
To use a fontless context, you must restore one of the predefined context files distributed with MIL (such as, "C:\Program Files\Matrox Imaging\contexts\FONTLESS_ANPR.msr").
Specifies the path and name of the file from which to restore the String Reader context (for example, "C:\mydirectory\myfile"). The function handles (internally) the opening and closing of the file.
The predefined context files, distributed with MIL, are in the "C:\Program Files\Matrox Imaging\contexts\FONTLESS_ANPR.msr" folder.
To open the file on the remote computer (under Distributed MIL), prefix the specified file name string with "remote:///" (for example, "remote:///C:\mydirectory\myfile").
This parameter can be set to one of the following:
For specifying the file name and
path
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_INTERACTIVE |
[This is
only applicable to Windows]
Opens the File Open dialog box from which you can interactively specify the drive, directory, and name of the file. |
||||||||||||||||||||||||||||||||||||||
MIL_TEXT("FONTLESS_ANPR.msr") 1 |
Specifies to restore a generic String Reader context useful to read license plates. |
||||||||||||||||||||||||||||||||||||||
MIL_TEXT("FONTLESS_EUROPEAN_ANPR.msr") 1 |
Specifies to restore a String Reader context useful to read European license plates. |
||||||||||||||||||||||||||||||||||||||
MIL_TEXT("FONTLESS_MACHINE_PRINT.msr") 1 |
Specifies to restore a special String Reader context that reads machine printed characters in Arial, OCR-B, or other sans-serif fonts. |
1 If you are passing the value in a variable, don't enclose it in MIL_TEXT().
Specifies the system on which to restore the String Reader context.
This parameter should be set to one of the following values:
For specifying the system
identifier
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_DEFAULT_HOST |
Specifies the default Host system of the current MIL application. |
||||||||||||||||||||||||||||||||||||||
MIL system identifier |
Specifies a valid system identifier, previously allocated using MsysAlloc(). |
Header | Include mil.h. |
Library | Use mil.lib; milstr.lib. |
DLL | Requires mil.dll; milstr.dll. |