MIL_TEXT_PTR MemPtrOrFileName, | //in-out |
MIL_ID SysId, | //in |
MIL_INT64 Operation, | //in |
MIL_INT64 StreamType, | //in |
MIL_DOUBLE Version, | //in |
MIL_INT64 ControlFlag, | //in |
MIL_ID *ObjectIdPtr, | //in-out |
MIL_INT *SizeByteVarPtr | //out |
This function can load or restore a MIL metrology context from a file or memory stream. All of the metrology context's settings and names that were in effect when the metrology context was saved will be restored. If you had associated a calibration context with the template reference in your metrology context and you did not save it with the context, you must re-associate the calibration context, using MmetControl() with M_ASSOCIATED_CALIBRATION. Also, if you had previously set drawing control types, using MgraControl() with M_DRAW_..., you must reset them since they were not saved with the context.
This function can also save a metrology context to a file or memory stream. All information about the previously allocated metrology context is saved, including all of the feature settings and geometric tolerance settings. However, any associated calibration contexts and drawing control type settings are not saved.
To inquire the number of bytes necessary to save a metrology context, you should call this function (MmetStream()) first with the Operation parameter set to M_INQUIRE_SIZE_BYTE.
The content saved to memory stream is equivalent to the content saved to file. In addition, any file saved with MmetSave() is equivalent to a file saved using this function.
You can use this and other MIL stream functions, for example, to save all required MIL objects, as well as any other custom data, for your application to a memory stream. Once in a memory stream, you can write the stream to a single file or transfer it over a network. You are responsible for concatenating the streams and for saving the stream to file.
Using MmetStream(), you can choose to save a backwards-compatible version of a MIL metrology context, which will work using a version of MIL that is up to one major release older than the current version (depending on which version is specified). For example, if you allocate a metrology context using MIL 9.0 and save it to version 8.0, you can restore this context on a computer where MIL 8.0 is installed. However, all settings and features unique to the higher version will be ignored when restored using the lower version. Besides saving backwards-compatible versions, you can also load or restore MIL metrology context saved using MIL version 8.0 or above. Settings that do not exist in the lower version will be filled with default values when the metrology context is loaded or restored.
Specifies the file or memory stream.
For specifying the name and path of a
file, memory stream or opening an interactive dialog
box
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_NULL |
Specifies to ignore this parameter. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_INTERACTIVE |
[This is
only applicable to Windows]
Opens a dialog box from which you can interactively specify the drive, directory, and name of the file, when the StreamType parameter is set to M_FILE. |
||||||||||||||||||||||||||||||||||||||
MIL_TEXT("FileName") 1 |
Specifies the drive, directory, and name of the file (for example, "C:\mydirectory\myfile"), when the StreamType parameter is set to M_FILE. (more details...) |
||||||||||||||||||||||||||||||||||||||
MemPtr |
Specifies the address of the block of memory, when the StreamType parameter is set to M_MEMORY. (more details...) |
1 If you are passing the value in a variable, don't enclose it in MIL_TEXT().
Specifies the system on which to restore the metrology context. For an M_RESTORE operation, set this parameter to one of the following values:
For a restore operation
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_DEFAULT_HOST |
Specifies the default Host system of the current MIL application. |
||||||||||||||||||||||||||||||||||||||
MIL system identifier |
Specifies a valid system identifier, previously allocated using MsysAlloc(). |
For M_INQUIRE_SIZE_BYTE, M_LOAD, and M_SAVE, this parameter must be set to the following value:
For a load or save operation, or when
inquiring the required number of bytes for a save
operation
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_NULL |
Specifies that this parameter is not applicable. |
Specifies the operation to perform. This parameter must be set to one of the following values:
For specifying the operation to
perform
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_INQUIRE_SIZE_BYTE |
Inquires the number of bytes required to save a metrology context. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_LOAD |
Loads the content of a specified file or memory stream into a previously allocated metrology context. |
||||||||||||||||||||||||||||||||||||||
M_RESTORE |
Restores a metrology context from a file or memory stream and assigns it an identifier. |
||||||||||||||||||||||||||||||||||||||
M_SAVE |
Saves a metrology context to a specified file or memory stream. |
Specifies the type of stream in which to store/from which to restore the metrology context.
This parameter must be set to one of the following values:
For the type of stream
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_FILE |
Specifies a file stream. |
||||||||||||||||||||||||||||||||||||||
M_MEMORY |
Specifies a memory stream. (more details...) |
Specifies the MIL version of the metrology context. This parameter must be set to one of the following values.
For specifying the MIL
version
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_DEFAULT |
Specifies the default version. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_PROC_VERSION_90 |
Sets the version to MIL 9.0. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_PROC_VERSION_90_PP1 |
Sets the version to MIL 9.0 Processing Pack 1. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_PROC_VERSION_90_PP2 |
Sets the version to MIL 9.0 Processing Pack 2. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_PROC_VERSION_100 |
Sets the version to MIL 10.0. (more details...) |
||||||||||||||||||||||||||||||||||||||
M_PROC_VERSION_100_PP1 |
Sets the version to MIL 10.0 Processing Pack 1. (more details...) |
Specifies whether to restore, from the file or memory stream, the calibration context associated with the template reference, or specifies to save, with the metrology context, the calibration context associated with the template reference.
For specifying whether to restore or save
the calibration contexts
|
|||||||||||||||||||||||||||||||||||||||
Value | Description
|
||||||||||||||||||||||||||||||||||||||
M_DEFAULT |
Specifies that the calibration contexts are not saved or restored. |
||||||||||||||||||||||||||||||||||||||
M_WITH_CALIBRATION |
Specifies that the calibration context is saved or restored, depending on the Operation parameter. (more details...) |
Specifies the address of the variable in which to write or from which to read the identifier of the metrology context.
For M_INQUIRE_SIZE_BYTE and M_SAVE operations, ObjectIdPtr specifies the address of the variable from which to read the metrology context identifier.
For an M_LOAD operation, ObjectIdPtr specifies the address of the variable from which to read the identifier of the metrology context where the file or memory stream content will be loaded.
For an M_RESTORE operation, ObjectIdPtr specifies the address of the variable in which to return the identifier of the restored metrology context. If the operation is not successful, M_NULL is returned.
Header | Include mil.h. |
Library | Use mil.lib; milmetrol.lib. |
DLL | Requires mil.dll; milmetrol.dll. |